/dev/sda
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.14-desktop-1omv4002] (OpenMandriva Lx 7.2-2)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue
Device Model: WDC WD10EZEX-08WN4A0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 02.01A02
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Sep 18 16:49:14 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10620) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 111) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 175 169 021 - 2233
4 Start_Stop_Count -O--CK 100 100 000 - 179
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 095 094 000 - 4332
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 174
192 Power-Off_Retract_Count -O--CK 200 200 000 - 30
193 Load_Cycle_Count -O--CK 200 200 000 - 162
194 Temperature_Celsius -O---K 107 098 000 - 36
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 48 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 24/37 Celsius
Lifetime Min/Max Temperature: 14/45 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (23)
Index Estimated Time Temperature Celsius
24 2021-09-18 08:52 37 ******************
... ..( 32 skipped). .. ******************
57 2021-09-18 09:25 37 ******************
58 2021-09-18 09:26 36 *****************
... ..( 10 skipped). .. *****************
69 2021-09-18 09:37 36 *****************
70 2021-09-18 09:38 35 ****************
... ..( 5 skipped). .. ****************
76 2021-09-18 09:44 35 ****************
77 2021-09-18 09:45 36 *****************
... ..(195 skipped). .. *****************
273 2021-09-18 13:01 36 *****************
274 2021-09-18 13:02 27 ********
275 2021-09-18 13:03 27 ********
276 2021-09-18 13:04 27 ********
277 2021-09-18 13:05 28 *********
278 2021-09-18 13:06 29 **********
279 2021-09-18 13:07 29 **********
280 2021-09-18 13:08 30 ***********
... ..( 2 skipped). .. ***********
283 2021-09-18 13:11 30 ***********
284 2021-09-18 13:12 31 ************
285 2021-09-18 13:13 31 ************
286 2021-09-18 13:14 31 ************
287 2021-09-18 13:15 32 *************
288 2021-09-18 13:16 32 *************
289 2021-09-18 13:17 32 *************
290 2021-09-18 13:18 33 **************
... ..( 2 skipped). .. **************
293 2021-09-18 13:21 33 **************
294 2021-09-18 13:22 34 ***************
... ..( 5 skipped). .. ***************
300 2021-09-18 13:28 34 ***************
301 2021-09-18 13:29 35 ****************
... ..( 15 skipped). .. ****************
317 2021-09-18 13:45 35 ****************
318 2021-09-18 13:46 36 *****************
... ..( 29 skipped). .. *****************
348 2021-09-18 14:16 36 *****************
349 2021-09-18 14:17 37 ******************
... ..( 28 skipped). .. ******************
378 2021-09-18 14:46 37 ******************
379 2021-09-18 14:47 36 *****************
... ..( 11 skipped). .. *****************
391 2021-09-18 14:59 36 *****************
392 2021-09-18 15:00 ? -
393 2021-09-18 15:01 24 *****
394 2021-09-18 15:02 24 *****
395 2021-09-18 15:03 25 ******
396 2021-09-18 15:04 25 ******
397 2021-09-18 15:05 26 *******
398 2021-09-18 15:06 27 ********
399 2021-09-18 15:07 28 *********
400 2021-09-18 15:08 28 *********
401 2021-09-18 15:09 28 *********
402 2021-09-18 15:10 29 **********
403 2021-09-18 15:11 29 **********
404 2021-09-18 15:12 30 ***********
... ..( 2 skipped). .. ***********
407 2021-09-18 15:15 30 ***********
408 2021-09-18 15:16 31 ************
409 2021-09-18 15:17 31 ************
410 2021-09-18 15:18 31 ************
411 2021-09-18 15:19 32 *************
... ..( 3 skipped). .. *************
415 2021-09-18 15:23 32 *************
416 2021-09-18 15:24 33 **************
... ..( 4 skipped). .. **************
421 2021-09-18 15:29 33 **************
422 2021-09-18 15:30 34 ***************
... ..( 6 skipped). .. ***************
429 2021-09-18 15:37 34 ***************
430 2021-09-18 15:38 35 ****************
... ..( 16 skipped). .. ****************
447 2021-09-18 15:55 35 ****************
448 2021-09-18 15:56 36 *****************
... ..( 20 skipped). .. *****************
469 2021-09-18 16:17 36 *****************
470 2021-09-18 16:18 37 ******************
... ..( 30 skipped). .. ******************
23 2021-09-18 16:49 37 ******************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 89 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 91 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 23382 Vendor specific
/dev/sdb
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.14-desktop-1omv4002] (OpenMandriva Lx 7.2-2)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Purple
Device Model: WDC WD10PURZ-85U8XY0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Sep 18 16:49:15 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (12960) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 147) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 124 121 021 - 4783
4 Start_Stop_Count -O--CK 100 100 000 - 255
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 093 093 000 - 5508
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 169
192 Power-Off_Retract_Count -O--CK 200 200 000 - 29
193 Load_Cycle_Count -O--CK 200 200 000 - 229
194 Temperature_Celsius -O---K 109 100 000 - 34
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 24/34 Celsius
Lifetime Min/Max Temperature: 0/43 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
00 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (190)
Index Estimated Time Temperature Celsius
191 2021-09-18 08:52 34 ***************
... ..(248 skipped). .. ***************
440 2021-09-18 13:01 34 ***************
441 2021-09-18 13:02 24 *****
442 2021-09-18 13:03 25 ******
443 2021-09-18 13:04 25 ******
444 2021-09-18 13:05 26 *******
445 2021-09-18 13:06 26 *******
446 2021-09-18 13:07 27 ********
447 2021-09-18 13:08 27 ********
448 2021-09-18 13:09 28 *********
... ..( 2 skipped). .. *********
451 2021-09-18 13:12 28 *********
452 2021-09-18 13:13 29 **********
453 2021-09-18 13:14 29 **********
454 2021-09-18 13:15 29 **********
455 2021-09-18 13:16 30 ***********
... ..( 2 skipped). .. ***********
458 2021-09-18 13:19 30 ***********
459 2021-09-18 13:20 31 ************
... ..( 5 skipped). .. ************
465 2021-09-18 13:26 31 ************
466 2021-09-18 13:27 32 *************
... ..( 4 skipped). .. *************
471 2021-09-18 13:32 32 *************
472 2021-09-18 13:33 33 **************
... ..( 6 skipped). .. **************
1 2021-09-18 13:40 33 **************
2 2021-09-18 13:41 34 ***************
... ..( 9 skipped). .. ***************
12 2021-09-18 13:51 34 ***************
13 2021-09-18 13:52 35 ****************
... ..( 68 skipped). .. ****************
82 2021-09-18 15:01 35 ****************
83 2021-09-18 15:02 ? -
84 2021-09-18 15:03 24 *****
85 2021-09-18 15:04 24 *****
86 2021-09-18 15:05 24 *****
87 2021-09-18 15:06 25 ******
88 2021-09-18 15:07 25 ******
89 2021-09-18 15:08 26 *******
90 2021-09-18 15:09 27 ********
91 2021-09-18 15:10 27 ********
92 2021-09-18 15:11 27 ********
93 2021-09-18 15:12 28 *********
... ..( 2 skipped). .. *********
96 2021-09-18 15:15 28 *********
97 2021-09-18 15:16 29 **********
98 2021-09-18 15:17 29 **********
99 2021-09-18 15:18 29 **********
100 2021-09-18 15:19 30 ***********
... ..( 4 skipped). .. ***********
105 2021-09-18 15:24 30 ***********
106 2021-09-18 15:25 31 ************
... ..( 5 skipped). .. ************
112 2021-09-18 15:31 31 ************
113 2021-09-18 15:32 32 *************
... ..( 7 skipped). .. *************
121 2021-09-18 15:40 32 *************
122 2021-09-18 15:41 33 **************
... ..( 11 skipped). .. **************
134 2021-09-18 15:53 33 **************
135 2021-09-18 15:54 34 ***************
... ..( 54 skipped). .. ***************
190 2021-09-18 16:49 34 ***************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 169 --- Lifetime Power-On Resets
0x01 0x010 4 5508 --- Power-on Hours
0x01 0x018 6 16991228002 --- Logical Sectors Written
0x01 0x020 6 123504846 --- Number of Write Commands
0x01 0x028 6 18428925929 --- Logical Sectors Read
0x01 0x030 6 79504109 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 5478 --- Spindle Motor Power-on Hours
0x03 0x010 4 5476 --- Head Flying Hours
0x03 0x018 4 259 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 2 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 34 --- Current Temperature
0x05 0x010 1 34 --- Average Short Term Temperature
0x05 0x018 1 32 --- Average Long Term Temperature
0x05 0x020 1 43 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 38 --- Highest Average Short Term Temperature
0x05 0x038 1 25 --- Lowest Average Short Term Temperature
0x05 0x040 1 33 --- Highest Average Long Term Temperature
0x05 0x048 1 27 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 2301 --- Number of Hardware Resets
0x06 0x010 4 1379 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 475 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 91 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 23379 Vendor specific