Probe #76ade477e8 of Dell Vostro 1500

Log: smartctl

/dev/sda smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.14-desktop-1omv4002] (OpenMandriva Lx 7.2-2) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint M8 (AF) Device Model: SAMSUNG HN-M320MBB Serial Number: -- LU WWN Device Id: 5 0024e9 ... Firmware Version: 2AR10001 User Capacity: 320,072,933,376 bytes [320 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Mar 28 10:57:39 2021 -04 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 254 (maximum performance), recommended: 254 APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 118) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: ( 5940) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 99) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 051 - 27546 2 Throughput_Performance -OS--K 055 051 000 - 5505 3 Spin_Up_Time PO---K 091 091 025 - 2852 4 Start_Stop_Count -O--CK 087 087 000 - 13565 5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0 7 Seek_Error_Rate -OSR-K 252 252 051 - 0 8 Seek_Time_Performance --S--K 252 252 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 9898 10 Spin_Retry_Count -O--CK 252 252 051 - 0 11 Calibration_Retry_Count -O--CK 069 069 000 - 31350 12 Power_Cycle_Count -O--CK 096 096 000 - 4358 181 Program_Fail_Cnt_Total -O---K 096 096 000 - 98458122 191 G-Sense_Error_Rate -O---K 075 075 000 - 255491 192 Power-Off_Retract_Count -O---K 252 252 000 - 0 194 Temperature_Celsius -O---- 060 052 000 - 40 (Min/Max 20/48) 195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0 196 Reallocated_Event_Count -O--CK 252 252 000 - 0 197 Current_Pending_Sector -O--CK 100 100 000 - 17 198 Offline_Uncorrectable ----CK 252 100 000 - 0 199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-K 001 001 000 - 71185 223 Load_Retry_Count -O--CK 069 069 000 - 31350 225 Load_Cycle_Count -O--CK 075 075 000 - 255420 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) Device Error Count: 27261 (device log contains only the most recent 8 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 27261 [4] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.395 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:01.395 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:01.395 READ DMA c8 00 ff 00 40 00 00 00 0c 18 c0 e0 00 00:00:01.395 READ DMA c8 00 ff 00 40 00 00 00 0c 18 80 e0 00 00:00:01.395 READ DMA Error 27260 [3] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 00 6b 65 d0 e0 00 Error: UNC 8 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 08 00 00 00 6b 65 d0 e0 00 00:00:01.342 READ DMA EXT 25 00 00 00 10 00 00 00 6b 65 b8 e0 00 00:00:01.342 READ DMA EXT 25 00 00 00 20 00 00 00 6b 65 80 e0 00 00:00:01.342 READ DMA EXT 25 00 00 00 08 00 00 00 6b 65 48 e0 00 00:00:01.342 READ DMA EXT 25 00 00 00 10 00 00 00 6b 65 20 e0 00 00:00:01.342 READ DMA EXT Error 27259 [2] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.323 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.311 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:01.299 READ DMA Error 27258 [1] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.311 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0c 18 c0 e0 00 00:00:01.299 READ DMA Error 27257 [0] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0c 18 c0 e0 00 00:00:01.299 READ DMA c8 00 ff 00 40 00 00 00 0c 18 80 e0 00 00:00:01.299 READ DMA Error 27256 [7] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 00 6b 65 d0 e0 00 Error: UNC 8 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 08 00 00 00 6b 65 d0 e0 00 00:00:00.993 READ DMA EXT 25 00 00 00 10 00 00 00 6b 65 b8 e0 00 00:00:00.993 READ DMA EXT 25 00 00 00 20 00 00 00 6b 65 80 e0 00 00:00:00.993 READ DMA EXT 25 00 00 00 08 00 00 00 6b 65 48 e0 00 00:00:00.993 READ DMA EXT 25 00 00 00 10 00 00 00 6b 65 20 e0 00 00:00:00.993 READ DMA EXT Error 27255 [6] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:00.974 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:00.962 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:00.950 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:00.950 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:00.950 READ DMA Error 27254 [5] occurred at disk power-on lifetime: 9794 hours (408 days + 2 hours) When the command that caused the error occurred, the device was in a vendor specific state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 30 00 00 00 6b 65 d0 e0 00 Error: UNC 48 sectors at LBA = 0x006b65d0 = 7038416 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:00.962 READ DMA c8 00 ff 00 40 00 00 00 6b 65 c0 e0 00 00:00:00.950 READ DMA c8 00 ff 00 40 00 00 00 0b 08 40 e0 00 00:00:00.950 READ DMA c8 00 ff 00 40 00 00 00 6b 0f c0 e0 00 00:00:00.950 READ DMA c8 00 ff 00 40 00 00 00 0c 18 c0 e0 00 00:00:00.950 READ DMA SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 60% 8578 417849160 # 2 Short offline Completed: read failure 90% 8575 417849160 # 3 Short offline Completed: read failure 80% 8562 417849160 # 4 Short offline Completed: read failure 80% 8551 417849160 # 5 Short offline Completed: read failure 90% 8539 417850384 # 6 Short offline Completed: read failure 90% 8529 417849160 # 7 Short offline Completed: read failure 90% 8514 417849160 # 8 Short offline Completed: read failure 90% 8499 417849160 # 9 Short offline Completed: read failure 70% 8487 417849160 #10 Short offline Completed: read failure 20% 8477 417849160 #11 Short offline Completed: read failure 60% 8465 417849160 #12 Short offline Completed: read failure 70% 8452 417849160 #13 Short offline Completed: read failure 90% 8441 417849160 #14 Short offline Completed: read failure 90% 8436 417849160 #15 Extended offline Completed: read failure 50% 8428 417849160 #16 Short offline Completed: read failure 70% 8415 417849160 #17 Extended offline Completed: read failure 50% 8406 417849160 #18 Short offline Completed: read failure 90% 8392 417849160 #19 Short offline Completed: read failure 70% 8379 417849160 #20 Short offline Completed: read failure 90% 8367 417849160 #21 Short offline Completed: read failure 90% 8360 417849160 SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed_read_failure [60% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 29/40 Celsius Lifetime Min/Max Temperature: 20/70 Celsius Specified Max Operating Temperature: 80 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 5 minutes Temperature Logging Interval: 5 minutes Min/Max recommended Temperature: -5/80 Celsius Min/Max Temperature Limit: -10/85 Celsius Temperature History Size (Index): 128 (114) Index Estimated Time Temperature Celsius 115 2021-03-28 00:20 40 ********************* 116 2021-03-28 00:25 37 ****************** ... ..( 4 skipped). .. ****************** 121 2021-03-28 00:50 37 ****************** 122 2021-03-28 00:55 38 ******************* ... ..( 2 skipped). .. ******************* 125 2021-03-28 01:10 38 ******************* 126 2021-03-28 01:15 39 ******************** 127 2021-03-28 01:20 40 ********************* 0 2021-03-28 01:25 39 ******************** 1 2021-03-28 01:30 40 ********************* 2 2021-03-28 01:35 39 ******************** ... ..( 3 skipped). .. ******************** 6 2021-03-28 01:55 39 ******************** 7 2021-03-28 02:00 38 ******************* 8 2021-03-28 02:05 38 ******************* 9 2021-03-28 02:10 39 ******************** ... ..( 2 skipped). .. ******************** 12 2021-03-28 02:25 39 ******************** 13 2021-03-28 02:30 40 ********************* 14 2021-03-28 02:35 39 ******************** 15 2021-03-28 02:40 39 ******************** 16 2021-03-28 02:45 39 ******************** 17 2021-03-28 02:50 38 ******************* ... ..( 4 skipped). .. ******************* 22 2021-03-28 03:15 38 ******************* 23 2021-03-28 03:20 39 ******************** 24 2021-03-28 03:25 39 ******************** 25 2021-03-28 03:30 39 ******************** 26 2021-03-28 03:35 40 ********************* 27 2021-03-28 03:40 39 ******************** ... ..( 20 skipped). .. ******************** 48 2021-03-28 05:25 39 ******************** 49 2021-03-28 05:30 38 ******************* ... ..( 3 skipped). .. ******************* 53 2021-03-28 05:50 38 ******************* 54 2021-03-28 05:55 39 ******************** 55 2021-03-28 06:00 39 ******************** 56 2021-03-28 06:05 39 ******************** 57 2021-03-28 06:10 38 ******************* 58 2021-03-28 06:15 38 ******************* 59 2021-03-28 06:20 38 ******************* 60 2021-03-28 06:25 39 ******************** 61 2021-03-28 06:30 39 ******************** 62 2021-03-28 06:35 38 ******************* 63 2021-03-28 06:40 39 ******************** 64 2021-03-28 06:45 42 *********************** 65 2021-03-28 06:50 39 ******************** 66 2021-03-28 06:55 39 ******************** 67 2021-03-28 07:00 38 ******************* 68 2021-03-28 07:05 38 ******************* 69 2021-03-28 07:10 38 ******************* 70 2021-03-28 07:15 39 ******************** ... ..( 2 skipped). .. ******************** 73 2021-03-28 07:30 39 ******************** 74 2021-03-28 07:35 38 ******************* 75 2021-03-28 07:40 38 ******************* 76 2021-03-28 07:45 38 ******************* 77 2021-03-28 07:50 37 ****************** 78 2021-03-28 07:55 37 ****************** 79 2021-03-28 08:00 36 ***************** 80 2021-03-28 08:05 36 ***************** 81 2021-03-28 08:10 36 ***************** 82 2021-03-28 08:15 37 ****************** 83 2021-03-28 08:20 38 ******************* 84 2021-03-28 08:25 38 ******************* 85 2021-03-28 08:30 38 ******************* 86 2021-03-28 08:35 39 ******************** 87 2021-03-28 08:40 32 ************* 88 2021-03-28 08:45 34 *************** 89 2021-03-28 08:50 35 **************** 90 2021-03-28 08:55 36 ***************** 91 2021-03-28 09:00 37 ****************** 92 2021-03-28 09:05 38 ******************* 93 2021-03-28 09:10 37 ****************** ... ..( 10 skipped). .. ****************** 104 2021-03-28 10:05 37 ****************** 105 2021-03-28 10:10 38 ******************* ... ..( 3 skipped). .. ******************* 109 2021-03-28 10:30 38 ******************* 110 2021-03-28 10:35 35 **************** 111 2021-03-28 10:40 38 ******************* 112 2021-03-28 10:45 39 ******************** 113 2021-03-28 10:50 39 ******************** 114 2021-03-28 10:55 40 ********************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x0008 4 0 Device-to-host non-data FIS retries 0x0009 4 7 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 6 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS 0x000f 4 0 R_ERR response for host-to-device data FIS, CRC 0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x8e00 4 0 Vendor specific 0x8e01 4 0 Vendor specific 0x8e02 4 0 Vendor specific 0x8e03 4 0 Vendor specific 0x8e04 4 0 Vendor specific 0x8e05 4 0 Vendor specific 0x8e06 4 0 Vendor specific 0x8e07 4 0 Vendor specific 0x8e08 4 0 Vendor specific 0x8e09 4 0 Vendor specific 0x8e0a 4 0 Vendor specific 0x8e0b 4 0 Vendor specific 0x8e0c 4 0 Vendor specific 0x8e0d 4 0 Vendor specific 0x8e0e 4 0 Vendor specific 0x8e0f 4 0 Vendor specific 0x8e10 4 0 Vendor specific 0x8e11 4 0 Vendor specific /dev/sdb smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.14-desktop-1omv4002] (OpenMandriva Lx 7.2-2) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Momentus 5400.3 Device Model: ST980811AS Serial Number: -- Firmware Version: 3.ALC User Capacity: 80,026,361,856 bytes [80.0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Sun Mar 28 10:57:40 2021 -04 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 426) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SCT capabilities: (0x0001) SCT Status supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 116 100 006 - 109043986 3 Spin_Up_Time PO---- 100 099 000 - 0 4 Start_Stop_Count -O--CK 096 096 020 - 4227 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 084 060 030 - 253592945 9 Power_On_Hours -O--CK 092 092 000 - 7219 10 Spin_Retry_Count PO--C- 100 100 034 - 0 12 Power_Cycle_Count -O--CK 096 096 020 - 4865 187 Reported_Uncorrect -O--CK 100 100 000 - 0 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 071 044 045 Past 29 (Min/Max 29/32) 192 Power-Off_Retract_Count -O--CK 100 100 000 - 1226 193 Load_Cycle_Count -O--CK 001 001 000 - 253649 194 Temperature_Celsius -O---K 029 056 000 - 29 (0 20 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 065 059 000 - 14517436 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 4 200 Multi_Zone_Error_Rate ------ 100 253 000 - 0 202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory not supported SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 SL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 SL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 SL R/O 1 NCQ Command Error log 0x11 SL R/O 1 SATA Phy Event Counters log 0x20 SL R/O 1 Streaming performance log [OBS-8] 0x21 SL R/O 1 Write stream error log 0x22 SL R/O 1 Read stream error log 0x23 SL R/O 1 Delayed sector log [OBS-8] 0x80-0x9f SL R/W 16 Host vendor specific log 0xa0 SL VS 1 Device vendor specific log 0xa1 SL VS 20 Device vendor specific log 0xa2 SL VS 101 Device vendor specific log 0xa8 SL VS 20 Device vendor specific log 0xa9 SL VS 1 Device vendor specific log 0xe0 SL R/W 1 SCT Command/Status 0xe1 SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 521 (0x0209) Device State: Active (0) Current Temperature: 29 Celsius Power Cycle Min/Max Temperature: --/ 0 Celsius Lifetime Min/Max Temperature: --/ 0 Celsius SCT Data Table command not supported SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron] Read SATA Phy Event Counters failed


Hardware for Linux and BSD

GitHub