Probe #30be24215f of Intel DB75EN Desktop Computer
Log: smartctl
/dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-164-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Blue Serial ATA
Device Model: WDC WD4000AAJS-00YFA0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 12.01C02
User Capacity: 400,087,375,360 bytes [400 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Thu Oct 12 18:24:25 2023 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10980) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 129) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 181 173 021 - 5933
4 Start_Stop_Count -O--CK 100 100 000 - 729
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 092 091 000 - 5841
10 Spin_Retry_Count -O--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 728
192 Power-Off_Retract_Count -O--CK 200 200 000 - 151
193 Load_Cycle_Count -O--CK 200 200 000 - 729
194 Temperature_Celsius -O---K 113 092 000 - 37
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 12 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 5795 -
# 2 Extended offline Completed without error 00% 1328 -
# 3 Short offline Completed without error 00% 263 -
# 4 Short offline Aborted by host 50% 203 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 34/37 Celsius
Lifetime Min/Max Temperature: 34/58 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 1/85 Celsius
Temperature History Size (Index): 128 (112)
Index Estimated Time Temperature Celsius
113 2023-10-12 16:17 44 *************************
... ..( 86 skipped). .. *************************
72 2023-10-12 17:44 44 *************************
73 2023-10-12 17:45 45 **************************
... ..( 27 skipped). .. **************************
101 2023-10-12 18:13 45 **************************
102 2023-10-12 18:14 ? -
103 2023-10-12 18:15 34 ***************
104 2023-10-12 18:16 34 ***************
105 2023-10-12 18:17 35 ****************
106 2023-10-12 18:18 35 ****************
107 2023-10-12 18:19 36 *****************
108 2023-10-12 18:20 36 *****************
109 2023-10-12 18:21 37 ******************
110 2023-10-12 18:22 37 ******************
111 2023-10-12 18:23 37 ******************
112 2023-10-12 18:24 44 *************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x8000 4 570 Vendor specific